QPREX
- Modular building system allows to realize customized volume up to 10m3. One of the system that offers the widest possibilities on the market. A single system of pressurization and washing can manage multiple modules in series.
- New gasket technology minimizes the dispersion of inactive gas, increasing efficiency of pressurized system and reduce operating costs
- QPREX pressurized panels, because of the continuous influx of purging gas, prevents the build up of heat and moisture and provide a greater life cycle of the equipment.
- Quick access: easy opening and maintenance, when the doors open the system disconnects; when the doors are closed again, after the washing cycle, the system will start again automatically.
- In QPREX can be mounted non Ex components.
- Logic TEX1 first company with SIL2 (Safety Integrity Level).
Material
Technical Features
AISI 316 L, AISI 304 or painted sendzimir steel
IP rating
Technical Features
IP65
Ambient temperature range
Technical Features
-50°C to +60°C
Approvals
Technical Features
TÜV 15 ATEX 158015 (pxb type of protection)
TÜV 15 ATEX 158016 (pzc type of protection)
IECEx TUN 15.0019 (pxb and pzc types of protection)
TÜV 15 ATEX 158016 (pzc type of protection)
IECEx TUN 15.0019 (pxb and pzc types of protection)
Marking
Technical Features
ATEX :
Ex px/pz [ia Ga] IIC T6 or T5 or T4 Gb/Gc
Ex px/pz [ia Ga] IIIC T85°C or T135°C Db/Dc
Ex px/pz [ia Ga] IIC T6 or T5 or T4 Gb/Gc
Ex px/pz [ia Ga] IIIC T85°C or T135°C Db/Dc
IECEx:
Ex pxb/pzc [ia Ga] IIC T6 or T5 or T4 Gb/Gc
Ex pxb/pzc [ia Ga] IIIC T85°C or T100°C or T135°C Db/Dc
Gaskets
Technical Features
EPDM or SILICONE
Dimensions
Technical Features
From 0,6 m3 to 10 m3
Tension
Technical Features
Up to 24 kVac / 1500 Vdc
Frequency
Technical Features
Up to 1000Hz
Pressurisation system
Technical Features
Technor Italsmea TEX1 (zone 1- SIL2 *) or TEX 2 (Zone 2) . Available with component certificate
Climatization
Technical Features
Vortex, Air conditioner, Cooling/heating water systems, Anticondensate heater.
Note
Technical Features
* SIL: Safety Integrity Level
TECHNICAL FEATURES
Material
AISI 316 L, AISI 304 or painted sendzimir steel
IP rating
IP65
Ambient temperature range
-50°C to +60°C
Approvals
TÜV 15 ATEX 158015 (pxb type of protection)
TÜV 15 ATEX 158016 (pzc type of protection)
IECEx TUN 15.0019 (pxb and pzc types of protection)
TÜV 15 ATEX 158016 (pzc type of protection)
IECEx TUN 15.0019 (pxb and pzc types of protection)
Marking
ATEX :
Ex px/pz [ia Ga] IIC T6 or T5 or T4 Gb/Gc
Ex px/pz [ia Ga] IIIC T85°C or T135°C Db/Dc
Ex px/pz [ia Ga] IIC T6 or T5 or T4 Gb/Gc
Ex px/pz [ia Ga] IIIC T85°C or T135°C Db/Dc
IECEx:
Ex pxb/pzc [ia Ga] IIC T6 or T5 or T4 Gb/Gc
Ex pxb/pzc [ia Ga] IIIC T85°C or T100°C or T135°C Db/Dc
Gaskets
EPDM or SILICONE
Dimensions
From 0,6 m3 to 10 m3
Tension
Up to 24 kVac / 1500 Vdc
Frequency
Up to 1000Hz
Pressurisation system
Technor Italsmea TEX1 (zone 1- SIL2 *) or TEX 2 (Zone 2) . Available with component certificate
Climatization
Vortex, Air conditioner, Cooling/heating water systems, Anticondensate heater.
Note
* SIL: Safety Integrity Level